Grenton Object Manager
Download the beta software and find out what's newBeta Version
v1.10.0 (build 241302)
9 April 2024
- Windows: v1.10.0 (build 241302)
- macOS: v1.10.0 (build 241302)
- Linux - GTK: v1.10.0 (build 241302)
What's new
v1.10.0 (build 241302)
- Added the ability to reverse state for
CONTACT_SENSOR
andCONTACT_SENSOR_DOUBLE
widgets. - Added myGrenton templates for
HEOS
andDenonMarantzAVR
objects. - Added missing myGrenton templates for objects of Analog IN/OUT, Multisensor, Touch Panel, Smart Panel, Dali, and GATE Modbus modules.
- Fixed the issue of excessively long wait time for user features refresh.
- Fixed default selection when choosing a script parameter.
- Fixed validation of entered value for BOOLEAN-type user feature.
Note!
For the state reversal functionality for widgets
For the state reversal functionality for widgets
CONTACT_SENSOR
and CONTACT_SENSOR_DOUBLE
, a minimum version of the myGrenton app 1.12.1 (iOS) or 1.9.17 (Android) is required.v1.9.0 (build 2409)
- Added copying of virtual objects.
- Added filtering of objects in the action configuration window.
- Added display of the number of used objects on CLU (visible on mouse hover) and a warning about exceeding the limit.
- Added the ability to replace modules of different types in the CLU Discovery process (e.g., CLU 1.0 with CLU 2.0).
- Added myGrenton templates for Jablotron objects.
- Fixed the default selection of CLU when copying scripts.
- Fixed binding errors in the myGrenton interface after changing the name in the object tree.
- Fixed an error in creating the SCENE widget for the script after replacing CLU.
- Fixed CLU code generation for setting user feature values from the myGrenton application - now values are set to the appropriate type.
- Fixed myGrenton interface generation in the script invocation area with a parameter as a feature.
- Fixed errors in the interface reload area.
- Fixed displaying Polish characters in the Diagnostic Logs window.
- Fixed errors in the area of adding actions for objects in a container.
- Fixed the problem of executing actions in the context of the previously opened configurator window.
- Fixed excessive collapsing and expanding of the object tree.
- Fixed the ability to delete containers with added objects.
- Removed Visual Builder.
- Changed the default setting of automatic interfaces base update when opening a project to active.
- Changed the maximum interface sharing time for myGrenton from 6 months to 2 years.
Note!
Automatic updating of the interfaces base when opening a project has been set as default. This setting can be changed by selecting Window->Preferences from the top menu.
Automatic updating of the interfaces base when opening a project has been set as default. This setting can be changed by selecting Window->Preferences from the top menu.
v1.8.2 (build 2402)
- Added
ROLLER_SHUTTER
andROLLER_SHUTTER_V3
myGrenton templates for ROLLER SHUTTER Z-Wave module.
v1.8.1 (build 2345)
- Added
VALUE_V2
myGrenton templates forZWAVE_ANALOG_SENSOR
,ZWAVE_BATTERY
,ZWAVE_1W_SENSOR
,ZWAVE_BINARY_SENSOR
andZWAVE_TAMPER_ALARM
objects. - Added
CONTACT_SENSOR
myGrenton templates forZWAVE_DIN
,ZWAVE_BINARY_SENSOR
,ZWAVE_TAMPER_ALARM
andSatelInput
objects. - Added
VALUE_DOUBLE
myGrenton templates forZWAVE_INFIBITY_DOOR_SENSOR
,ZWAVE_INFIBITY_WATER_SENSOR
andZWAVE_INFIBITY_MOTION_SENSOR
modules.