Smart Panel Firmware
Download the software and find out what is in the releasesWhat's New
- Support for DistributedLogic mode, that enables functioning of the Grenton Tf-Bus modules without the CLU control unit. The DistributedLogicGroupX parameter has been added to each of the 4 objects assigned to the page object (PANELPAGE). This parameter enables pairing sensor devices with actuator devices without the presence of CLU.
- The new DrawBox(x,y,w,h,color) method in the PANEL object, that draws a rectangle with specified color. Method is useful when clearing a change area displayed by the OLED. This avoids clearing the entire screen, and therefore is more efficient.
- The new Calibration feature in the PANELSENSTEMP object, that gives temperature calibration with a constant value from -10 to +10°C.
- The new OnDisplayOn/OnDisplayOff events in the PANEL object, that are generated when the OLED display is turned on and off.
- The new thermostat interface in the PANELPAGE object, that contains:
- Executing user action after a short press of the upper left "mode" button of Smart Panel. The new functionality generates the OnThermXModeButtonClick event.
- Displaying user icon in the upper left corner of the OLED using the SetObjectXCustomIcon(bmp) method and the ObjectXCustomIcon feature.
- The OFF/AUTO/MAN thermostat operating mode was moved before the set temperature.
- A long press of upper right "next" button or a short press in case just one thermostat is configured switches to the next page.
- The 2-pixels frame between the buttons has been removed. This makes it possible to display a big icon 128x64 (4 x 64x32) without the separation of the black cross in Button mode.
- The behavior of the FreeDraw page has been changed. The DisplayContent() method is automatically executed after a 2-second timeout has expired since the start of drawaing. At the same time a low buzz sound is generated indicating a misconfiguration.
- Fixes in the area of displaying icons / button descriptions.
- Improved button responsiveness for configured icons.
- Fix in the OnProximityDetect event generation.
- The signaling of the lack of receiving the configuration from the CLU has been added. it is one beep after 10s from restarting the device.
Note!
Smart Panel FW version 6.01.08-2115 is supported be the CLU Z-Wave 2.0 FW version 5.08.01 (or higher). As the configuration tool there must be used Object Manager v1.4.1 (or higher).
Smart Panel FW version 6.01.08-2115 is supported be the CLU Z-Wave 2.0 FW version 5.08.01 (or higher). As the configuration tool there must be used Object Manager v1.4.1 (or higher).
Note!
Due to the renaming of the following events, the actions added to them will be removed when assigning active modules to inactive ones: PANELBUTTON object – the name of the OnChange event has been changed to OnValueChange ; PANELSENSTEMP / PANELSENSLIGHT object – OnChange, OnRaiseValue, OnLowerValue event names have been changed to OnValueChange, OnValueRise and OnValueLower.
Due to the renaming of the following events, the actions added to them will be removed when assigning active modules to inactive ones: PANELBUTTON object – the name of the OnChange event has been changed to OnValueChange ; PANELSENSTEMP / PANELSENSLIGHT object – OnChange, OnRaiseValue, OnLowerValue event names have been changed to OnValueChange, OnValueRise and OnValueLower.