Installation and start-up processInstallation and start-up process
Note! - GATE Alarm 1.0!
The new firmware version is not compatible with projects created for GATE Alarm fw. 18.19.x and 18.20.x. Using projects from these versions can corrupt the entire project. In this case, the updated firmware can only be used for new projects !!!
The new firmware version is not compatible with projects created for GATE Alarm fw. 18.19.x and 18.20.x. Using projects from these versions can corrupt the entire project. In this case, the updated firmware can only be used for new projects !!!
- Run the Object Manager program in the required version for the given GATE firmware (Changelog section for a given module).
- Open the last submitted project.
- Make sure that no changes have been made to the project - there is no
*
next to the GATE icon. - Update the interface database:
- Select "Tools" from the menu bar.
- Select the „interface base” option.
- Select the "Update interfaces base" option from the displayed list.
- Make a configuration change, and then send it to the GATE module.
- Perform a firmware update on GATE:
- Select „Tools” from the menu bar.
- Select “Update firmware”
- Select the
CLU_GATE
type object. Selecting the check box is only possible if the current firmware on the GATE is out of date. - Select „Update”
- After reading the message, select "Yes" - after accepting, the update process will start.
Note!
During the upgrade process, do not turn off the power or perform other activities on the system. For the update to be successful, you must complete it to the end.
During the upgrade process, do not turn off the power or perform other activities on the system. For the update to be successful, you must complete it to the end.
- If the update is successful, [UPDATED] appears when the GATE is updated correctly.
- Close the update process window.
- If the update was successful, the firmware version after refreshing should be in accordance with selected to update.
- Perform „CLU Discovery”.
Note!
After CLU Discovery is completed, you may receive a message regarding the configuration being sent to GATE. If the message occurs, click "OK", finish the Discovery process and then reload the interface database.
After CLU Discovery is completed, you may receive a message regarding the configuration being sent to GATE. If the message occurs, click "OK", finish the Discovery process and then reload the interface database.
- Reload interfaces base:
- Select „Tools” from the menu bar.
- Select „Update firmware”.
- Select the option "Reload interface interface" from the displayed list.
- Apply changes by selecting "Yes".
- Make a configuration change, and then send it to the GATE module.