GATE Alarm 2.0 Firmware
Download the software and find out what is in the releasesFirmware Update
Current Version: 1.4.2 (build 2346)
- Firmware is accessible from the Object Manager tool.
Changelog
v1.4.2 (build 2346)
20 December 2023
- Support for diagnostic logging using telnet. Added new method (SetTelnetLogLevel) and feature (TelnetLogLevel) for setting log level.
- New features for the GATE object:
- OverloadDetection feature - the ability to detect processor overload using a red LED.
- ResetReason feature - diagnostic function that determines the reason for module restart.
- Added UTC time to the list of time zones.
- Fixes in the area of zone / output deactivation for Satel.
- Bug fixes, improved device stability and performance.
v1.1.20 (build 2219)
5 December 2022
- Support for the Jablotron JA-100, JA-103 and JA-107 alarm control panels.
- Bug fixes.
Note!
To be able to update GATE to 1.1.20, you must have Object Manager v1.4.1 (or higher).
To be able to update GATE to 1.1.20, you must have Object Manager v1.4.1 (or higher).
v1.1.11 (build 2218B)
16 May 2022
- Bug fixes, improved device stability and performance.
Note!
To be able to update GATE to 1.1.11, you must have Object Manager v1.4.1 (or higher)
To be able to update GATE to 1.1.11, you must have Object Manager v1.4.1 (or higher)
v1.1.10 (build 2140)
29 March 2022
- Bug fixes, improved device stability and performance.
Note!
To be able to update GATE to 1.1.10, you must have Object Manager v1.4.1 (or higher)
To be able to update GATE to 1.1.10, you must have Object Manager v1.4.1 (or higher)
v1.1.0 (build 2034C)
14 October 2020
- Setting the GATE time using the NTP server including the time zone and changing the time (winter / summer). The time is taken automatically from the NTP server (pool.ntp.org). There are three new features of the GATE to configure:
- UseNTP - determines whether GATE uses NTP;
- NTPTimeout - waiting time for a response from the NTP serve;
- TimeZone - setting the GATE time zone - 22 zones are available.
Note!
Downloading time from the server requires GATE to be in a network that has an Internet connection.
Downloading time from the server requires GATE to be in a network that has an Internet connection.
- New features related to the presentation of time on GATE:
- Date - returns the current date;
- Time - returns the current time (hh: mm: ss);
- LocalTime / UnixTime - features that return a local / Unix timestamp.
- Changing the network gateway for the added GATE module - the ability to change the gateway during CLU Discovery.
- Improved handling of incorrect incoming frames from the Satel alarm control.
- Improved device stability.